Recommendations pertinent to fff technology, including acceptance testing, commissioning, quality assurance, radiation safety, and facility. Vendorspecific gantry mounts for rotational testing optionally available. Flattening filter free fff beams have reached widespread use for clinical treatment deliveries. This technology allows users to choose which data parameters to view and over what period to view them. Many studies have confirmed improvement in delivery efficiency by removing the ff, also known as flattening filter free fff, especially for small field stereotactic body radiation therapy sbrt. The qa beamchecker plus allows for fast, reliable, and. Flattening filter free beam parameters machine qa module. Varians portal dosimetry is an electronic portal imager device epid. Flattening filter free fff beams may increase dose rates and lower peripheral dose. Unflattened photon beams from the standard flattening. First elekta versa hd signature model linearaccelerator commissioned in bangladesh.
Elektas flattening filter free fff beam generation technology ensures matching between beams with and without the flattening filter. Motive of the study is to present quantitative and qualitative analysis and comparison of beam data measurement with ff flattening filter and fff flattening filter free beam in a varian truebeamtm medical linear accelerator. Introduction the dosimetry accuracy is an important factor in the field of radiation therapy. The flattening filter was first introduced to provide flat dose profiles at a certain depth. We investigated fff for leftsided breast irradiation, comparing 4 intensitymodulated radiation therapy techniques in 10 patients using flattened or fff beams. Dedicated for highdoserate fff and conventional measurements. Pretreatment quality assurance of flattening filter free beams on 224 patients for intensity modulated plans. Varian truebeam flatteningfilterfree mode photon beams usually have a metal filter on their path to make photon fluence uniform or flat.
Todd pawlicki, sua yoo, et al, moving from imrt qa measurements toward independent computer calculations using control charts. The impact of flatteningfilterfree beam technology on 3d. Brigham and womens hospital department of radiation oncology 75 francis street boston, ma 02115 research location. Pretreatment quality assurance data from four centers, members of the european truebeam council were analyzed with different verification devices to assess reliability of flattening filter free beam delivery for intensity modulated. Benchmarking flattening filterfree photons for imrtvmat. Quality assurance of fff beams flattening filter free fff fff beams are used in the linac without ff in place of carousel. Thinkqa is the first software suite dedicated for patient specific qa, that. Because of the high dose rate muminute, dosimetric properties of these fff xrays need to be carefully studied. Characterisation of flattening filter free fff beam.
Both the 6 and 10 mv fff beams use a tungsten target. Advanced treatment techniques, such as stereotactic radiotherapy or intensity modulated radiotherapy have stimulated the interest in operating linear accelerators in a flattening filter free fff mode. The qa beamchecker plus is capable of handling output measurements for the most advanced accelerator modes, such as flatteningfilter free beams using the integrated baseline comparison for easy tracking and trending of values. A report on flattening filter free linear accelerators. In recent years, the application of the flatteningfilterfree fff photon beam. Flattening filter free fff high dose rate beams is one of the cutting edge technologies. Fff delivered with conventional medical linear accelerator have the conical. Woo, an analysis of tolerance levels in imrt quality assurance procedures, med. A screen capture from the delta4 software showing the two panels and the. Monte carlo investigation into feasibility and dosimetry of. Validation of patient specific quality assurance of. For constancy tests of flattening filter free fff radiation fields. Linac commissioning, annual qa, gamma analysis, tg 142, flattening filter and flattening filter free beams 1.
Commissioning of truebeam tm medical linear accelerator. If this is the case, then there will be an etalon ripple superimposed on the desired filter shape. Optimized design for workflow efficiency from setup to measurements and analysis. Photons are absorbed reduced efficiency photons are scattered increased contamination radiation neutrons are produced increased contamination radiation flat profile only flat at one depth patients and tumors arent flat can it be removed. Absolute dose calibration for operation of the flatteningfilter free mode of a truebeam stx linac john frame, kirstie brown, martin ford. By using a quickcheck fff compensator, all quickcheck measurements can be performed as usual. Piotr zygmanski, phd, dabr associate research associate, brigham and womens hospital assistant professor of radiation oncology, harvard medical school.
On the determination of reference levels for quality assurance of flattening filter free photon beams in radiation therapy a. The removal of the filter will also reduce the scatter dose outside the field. Poster pretreatment quality assurance for flattening. A 2d diode array and analysis software for verification of intensity modulated radiation. Introduced in march 2007, prior to the advent of these newer machines, the qa beamchecker plus was not designed to be. At its heart are over 0 sunpoint diode detectors providing consistent and highly sensitive measurements for all gantry angles, with no additional hardware required. We hypothesized the calibration for the flattenfilterfree fff beam is more vulnerable to. Introduced in march 2007, prior to the advent of these newer machines, the qa beamchecker plus was not designed to be compatible with dose rates delivered by fff beams. Deliver 40% faster treatments with rapid leaf speed and high dose rate mode.
Flattening filter free fff beams generated by medical linear. Pretreatment quality assurance of flattening filter free. Filterpro mfb and sallenkey design program designs lowpass and highpass filters using opamps, resistors, and capacitors. The ff in a standard linac is located between the primary collimator and the monitor chamber and its main role is to make the photon beam dose distribution uniform at reference depth within the allowed variations. Definition of parameters for quality assurance of flattening filter free fff photon beams in radiation therapy. Pretreatment quality assurance qa with flattening filter free fff beams is challenging because of the high dose rate and the required spatial resolution as small fields are usually used. Benchmarking flattening filterfree photons for imrtvmat using tg119 by sarah ashmeg. The development of imrt eliminates the need for a flattening filter in modern linear accelerator linac systems. This tool lacks the capability of verifying flattening filter. Calculated target volume, heart, and ipsilateral lung doses were similar. Our current clinical practice is to perform pretreatment qa with a chamber array in a rotational phantom. Monte carlo investigation into feasibility and dosimetry.
In the flattening filter free mode a 6 mm thick copper disk was positioned in the filter carousel and rotated into the beam instead of the flattening filter. A modification of flattening filter free linac for imrt. Infinity is the workhorse system you need now to maximize your departmental performance. It is possible to adapt fff beams flatteningfilterfree in 3d conformal radiation therapy 3d crt by using field in field techniques fif. We implemented the gafchromic filmbased patient specific qa of volumetric modulated arc therapy vmat with flatteningfilter free fff beams for spine metastases and validated the accuracy of fast arc delivery. Thinkqa is the first software suite dedicated for patient specific qa, that provides an independent secondary mu calculation, as well as epid based solutions for pretreatment beam verification and in vivo dosimetry, all at once while on the hospital network, all of patient qa outcomes are accessible anytime and anywhere through an intuitive, ergonomic and collaborative interface. With coherent light, any type of filter can act as a fabryperot etalon if the two surfaces of the filter are sufficiently parallel and if the secondary surface of the filter is not antireflection ar coated. Fff compensators are available for x6 and x10 fff radiation fields. Data from high dose rate and flattening filter free capable machines such as the varian. Flattening filter free fff linac radiation oncology. Fogliata a et al 2016 flattening filter free beams from truebeam and versa hd units. Deliver a unique plan with a dynamic wedge included to assess the core functionality of it.
Flattening filter free xrays have significantly shorter treatment time if is used for small field applications, such as. Critique of beam characterization and evolution of dosimetric properties for 6 mv, 10 mv, 15 mv ff beam and 6 mvfff, 10 mvfff fff beam has been carried out. Flattening filter free, medical accelerator, photon beam, quality assurance, unflat photo beam. Apr 20, 2018 pretreatment quality assurance qa with flattening filter free fff beams is challenging because of the high dose rate and the required spatial resolution as small fields are usually used. Definition of parameters for quality assurance of flattening filter free.
With proliferation of accurate treatment planning algorithms and intensitymodulated radiation therapy imrt the uniform fluence is not a concern. Pinnacle3 modeling and endtoend dosimetric testing of a versa. Acceptance and commissioning was performed on the elekta versa hd linac with five photon energies 6mv, 10mv, 15mv, 6mv fff, 10mv fff, five. Fast and intuitive, from measurement setup to analysis. Definition of parameters for quality assurance of flattening. Modification of fff beam parameters is explored to maximize the monitor unit efficiency and to minimize. A sensitivity dosimetry study of the setup uncertainties. For these techniques flattening filter free fff beam is a better choice with which treatment time can cut down to 24 times over conventional flattened beams fb due to high dose rate capability. Fff beam qa thena flattening filter free beam parameters machine qa module provides physicist with following tools implementation of fff beam parameters evaluation determination of the core beam parameters and its long term stability as proposed in paper published in medical physics, volume 39, no. The purpose of this study was to compare the performance of different commercial quality assurance qa systems for the pretreatment verification plan of stereotactic body radiotherapy sbrt with volumetric arc therapy vmat technique using a flatteningfilterfree beam. Small field dosimetry and analysis of flattening filter.
On the determination of reference levels for quality assurance of flattening filter free photon beams in radiation therapy. Without the presence of the attenuating filter, the incident photon fluence rate will increase by a factor to two or more, resulting in shorter treatment times. Varian truebeam flatteningfilterfree mode sudentas. Reduce leakage from the treatment head, they have 50% to 60% reduced collimator and treatment head scatter. Daily qa 3 software provides a graphical presentation of radiation oncology beam measurement data.
Beams produced without a flattening filter offer some advantages over conventional flattened beams. Request pdf definition of parameters for quality assurance of flattening filter free. Thinkqa suite fullweb, full compatibility, full quality for your qa tasks thinkqa is the first software suite dedicated for patient specific qa, that provides an independent secondary mu calculation, as well as epid based solutions for pretreatment beam verification and in vivo dosimetry, all at once. Arccheck is the only true 4d array specifically designed for qa of todays modern rotational deliveries. This program supports bessell, butterworth, and chebychev filter types. Flattening filter free fff linac in march 20 the first patient was treated in mannheim with a flattening filter free fff linear accelerator. Supports imrt, rotational patient plan verification as well as machine qa. On the determination of reference levels for quality assurance of flattening filter free. The dosimetric accuracy is affected not only by the quality of the linear accelerator linacs.
To investigate the sensitivity of various gamma criteria used in the gammaindex method for patientspecific volumetric modulated arc therapy vmat quality assurance qa for stereotactic body radiation therapy sbrt using a flattening filter free fff photon beam. The compensator can easily be used by placing it on top of the quickcheck webline device. Piotr zygmanski, phd, dabr department of radiation oncology. Unique universal detector for patient qa and machine qa. Absolute dose calibration for operation of the flattening. Vmat cases for 10 mv flattening filter free fff, high dose regions first 6. Electrons produced in the copper filter are needed to provide the monitor chamber with sufficient signal to allow a stable operation of the beamservo system 11, 14.
Imrt cases for 10 mv flattening filter free fff, high dose regions first 6 sites to the left and low dose regions 7 sites to the right 36 figure 24. With versa hd, clinicians can be confident that the dose is consistently placed as they planned it. Introduction photon beams are generated by bombarding a highz target with a highenergy electron beam. Three types of intentional misalignments were introduced to original highdefinition multileaf collimator hdmlc plans. Quickcheck webline ptw freiburg gmbh ptw dosimetry. A standard linac uses a flattening filter ff in photon mode operation while helical and robotic linacs do not have flattening filters. The purpose of this study was to report the dosimetric characteristics of the small fields in flattening filter free fff beams output measurements, profile analysis, surface dose and consistency generated by medical linear accelerator and its variation with respect to flattened beams fb. Unflattened photon beams from the standard flattening filter. Flattening filter free fff high dose rate beams is one of the cutting edge technologies introduced by linear accelerator linac manufacturers which enable the clinical community to deliver highly precise, accu rate and rapid treatment for better clinical results. The removal of the flattening filter ff leads to nonuniform fluence distribution with a considerable increase in dose rate. Flattening filters ffs have been considered as an integral part of the treatment head of a medical accelerator for more than 50 years. Imrt cases for 6 mv flattening filter free fff, high dose regions first 6 sites. Energy and angular spread of the electron beam of the fff linac were modified. Flattening filter free vs flattened beams for breast.
It is possible to adapt fff beams flattening filter free in 3d conformal radiation therapy 3d crt by using field in field techniques fif. Individuals should assess risks based on their clinical practiceprocedures. First elekta versa hd signature model linearaccelerator. Ebt3 films and a homemade cylindrical qa phantom were employed for dosimetric verification of vmats. This technology measures the output, flatness, symmetry, field size, and energy of rotational and flattening filterfree fff beams. Gain flattening filter gff tutorial gain flattening filter gffs, also known as gain equalizing filters, are used to flatten or smooth out unequal signal intensities over a specified wavelength range. The aim of this retrospective study is to clarify whether the quality of 3d crt plans is influenced by the use of fff beams. This study investigates the benefits of a modified flattening filter free fff linac over the standard std linac equipped with the flattening filter. The usual methods for fff beam characterisation for their quality assurance qa require the use. Dose calibration curve generated for 6x using film qa pro software, average response for 10gy over central. Photons are absorbed reduced efficiency photons are scattered increased contamination radiation neutrons are produced increased contamination radiation flat profile only flat at one depth. The usual methods for fff beam characterisation for their quality assurance qa require the use of associated conventional flattened beams cff. Validation of patient specific quality assurance of flattening filter free fff based volumetric modulated arc therapy.
May 26, 2016 quality assurance of fff beams flattening filter free fff fff beams are used in the linac without ff in place of carousel. Both applications powered by the myqa global qa platform. In recent years, the application of the flattening filter free fff photon beam has been studied extensively 5, 716. Dosimetric and biologic differences in flattened and. Small field dosimetry and analysis of flattening filter free. A comprehensive calibration methodology coupled with a novel virtual inclinometer. We implemented the gafchromic filmbased patient specific qa of volumetric modulated arc therapy vmat with flattening filter free fff beams for spine metastases and validated the accuracy of fast arc delivery. Lang et al optimizing the accuracy of a helical diode array dosimeter. With the removal of the flattening filter dose rates up to four times higher than with flattening filter are feasible, while reducing the scattered radiation. Introduction photon beams are generated by bombarding a high. Tsiamas p1, seco j, han z, bhagwat m, maddox j, kappas c, theodorou k, makrigiorgos m, marcus k, zygmanski p. The number of beams pulses per second remains the same 360 pulsessecond at the maximum dose rate, however, the absence of attenuation due to the metal filter results in higher photon dose in the central portion of the beam.
The qa beamchecker plus is capable of handling output measurements for the most advanced accelerator modes, such as flattening filter free beams using the integrated baseline comparison for easy tracking and trending of values. Ionrecombination of ionization chambers is a concern. A report on flattening filter free linear accelerators from the therapy emerging technology assessment work group ying xiao, stephen f. Jul 28, 2014 to investigate the sensitivity of various gamma criteria used in the gammaindex method for patientspecific volumetric modulated arc therapy vmat quality assurance qa for stereotactic body radiation therapy sbrt using a flattening filter free fff photon beam. Inaccurate positioning might introduce significant calibration. Matrixx ionization chamber detector arrays are designed for fast and accurate verification of patient dose, as well as linac qa.
In march 2010, the true beam linac vms introduced clinically the flattening filterfree. The line labeled 10fff blue is the new flattening filter free fff mode. The qa beamchecker plus is used to perform routine daily qa measurements for traditional linear accelerators and rotational vmat systems including those from varian, elekta, siemens, and accurays tomotherapy and cyberknife. However, portal dosimetry cannot be applied to imrt or vmat with flattening filterfree fff beams because of the high doserate saturation effect of the electronic portal imaging device epid.